Description:
Acceptance Criteria: ________ colour tubular borosilicate glass vials.
Overflow Capacity : Check the overflow capacity of bottle by adding water in to it.
Acceptance criteria : _____ ± 10 %
Weight : Check the average weight of the bottles.
Acceptance criteria : _____ ± 5 %
Body Diameter : Check the diameter of body of bottle with vernier caliper.
Acceptance criteria : _______ ± 1 mm
Height : Check the total height of bottle with vernier caliper.
Acceptance criteria : _______ ± 1 mm
Rim Outer Diameter : Check the outer diameter of the bottle with vernier caliper.
Acceptance criteria : _______ ± 1 mm
Rim Inner Diameter : Check the inner diameter of the bottle with vernier caliper.
Acceptance criteria : _______ ± 1 mm
Rim Thickness Diameter : Check the thickness of the bottle with vernier caliper.
Acceptance criteria : _______ ± 1 mm